AC/DC RCBO (4P, electro-magnetic type)

RCBO (8 series)

Residual current operated circuit breakers with integral overcurrent protection (RCBO) of 8 series provide full protection to both installation and persons, as they are able to automatically switch off the power supply in case of overload, short-circuit and earth leakage. RCBO perform the same functions as both MCB and RCCB combined in a single product. Their use is suggestable whenever it is necessary to reduce at most the available space, guaranteeing the operator’s safety and the protection of the installation and the connected equipment.

Product images

type-a-rcbo-3P+N-greegoo type-a-rcbo-3P+N-greegoo type-a-rcbo-3P+N-greegoo type-a-rcbo-3P+N-greegoo

Features



-

-
8 series offers a complete range of RCBO. According to the wave form of the leakage current they are sensitive to, the RCBO can be classified as follows:
AC type:suitable for all electric installations which may include devices featuring a possibly sinusoidal alternate faults current.
A type: suitable where the connectable electric devices have electronic rectifiers or electronic circuits regulating the current wave form because it operates in presence of fault current either of alternate or pulsating type.


-

-
Depending on their intervention sensitivity, the RCBO can be classified as follows:
Low Sensitivity (IΔn = 0,1A - 0,3A - 0,5A): not suitable to protect from direct contacts; they are instead suitable for the indirect contacts, providing a proper coordination with the earth-circuit is made as explained on page 14.
High Sensitivity (IΔn = 0,01A - 0,03A): suitable to protect from both direct and indirect contacts.

Model explanation

type-a-rcbo-3P+N-model-explanation-greegoo

Parameters for magnetic type RCBO:

Product type Magnetic type
Reference standard EN 61009-1
Number of poles 3P+N
Number of moudles 4
Rated voltage 400V~
Rated current at 30oC (IN) 10A-40A
Tripping characteristics* B/C
Rated breaking capacity (A) 6.000
Rated residual making-breaking capacity IΔm (A) 3.000
Type A
Rated residual current IΔn (mA) 30/100/300/500
Number of Electrical operations (No cycles C-O) 10.000
Number of Mechanical operations (No cycles C-O) 20.000
Rated frequency 50/60 Hz
Protection degree IP20
Fire resistance(Glow wire test) 960oC
Maximum cross-section of connectable cable(flexible/rigid) 25/35 mm2

Dimensions

dimension

Related Products:
1P+NA RCBO (GDS9 Electro-magnetic type)
Electro-magnetic type RCBO (1P+N)
Type A RCBO (2P, electro-magnetic type)

                  




Home | Site Map | Air Circuit Breaker (ACB) | Molded Case Circuit Breaker (MCCB) | Earth Leakage Circuit Breakers (ELCB) | Manual Motor Starter (MPCB)
Recommend Products: 1P+NA RCBO (GDS9 Electro-magnetic type) | Single Phase Modular Energy Meters (GEM011AG) | Surge Protection Devices (Surge Arrester, MOV 10kA upto 60kA) | Moulded Case Circuit Breaker (MCCB 1250A electronic type) | RCBO Circuit Breakers (1P+N, electronic type)

 
Copyright 2007 Greegoo All Right Reserved